User Manual

TP10313-1 PAGE 24
6.2 Run Time Fault Messages
Run time fault messages are only displayed when the unit is in Run mode. Fault errors can still occur, but the corresponding
fault message will not be displayed until the unit is switched to Run mode. Run time fault messages are PLC System Errors
or errors in the whole Electric System. It is necessary to call a technician or service.
ENGLISH GERMAN CODES TYPE DESCRIPTION
DCT X.X.X DCT X.X.X DCT X.X.X Information This is the Software-Version(X.X.X)
Note: do not push any buttons until this message has been
cleared from the display
K5 Relay K5 Relay Error 7 PLC System The drive stop relay, K5, is not responding to the controller.
Error Action: Call service.
Button Taste Error 8 Electrical A push button is in the wrong state during the version message
System display. Action: Check Buttons & Cycle Power. If error
Error persists call service.
Watchdog Watchdog Error 9 PLC System The Watchdog Timer has elapsed without being serviced.
Error Action: Cycle Power. If error persists call service.
No Tach Impuls Error10 Electrical The Machine Tachometer is reading a velocity outside of the
System range 10 – 230 meters per minute, while the main drive should
Error be running. Action: Check the electric. If error persists call
service.
Overload Uberlast Error11 Electrical A Thermal Overload has been tripped.
System Action: Check the electric. If error persists call service.
Error
Pile Err Spg.Uber Error12 Electrical The Pile Safety Relay is stuck on or there is no power supply to
System the pile circuits. Action: Check the condition of Relay 1 (K1),
Error Fuses F1 and F2, and X18, then cycle Power. If error persists
call service.
Overrun Uberlauf Error13 Electrical The Pile Table has moved past its safety stops. Action: Check
System the limit switches, pile table, and wiring. If error persists call
Error service.
2
nd
Stat 2Station Error14 Electrical The Emergency Stop, Wrong Sheet, and Thermal Overload
System sense circuits are all indicating failure. Likely cause is Second
Error Station connector problems. Action: Check the Second Station
Connector, connector X22, and each individual circuit. If error
persists call service.
Suction Saugtakt Error15 Electrical Short circuit on Suction controller. Action: Check the electrics.
System If error persists call service.
Error
Table 17. Run Time Fault Messages