6.2 Run Time Fault Messages
Run time fault messages are only displayed when the unit is in Run mode. Fault errors can still occur, but the corresponding
fault message will not be displayed until the unit is switched to Run mode. Run time fault messages are PLC System Errors or
errors in the whole electric system. It is necessary to call an technician or service.
English German Codes TYPE DESCRIPTION
DCT DCT DCT Information This is the Software-Version(X.X.X)
X.X.X X.X.X X.X.X Note:do not push any buttons until this message has been
cleared from the display
K5 Relay K5 Relay Error 7 PLC System The drive stop relay, K5, is not responding to the controller.
Error Action: Call service.
Button Taste Error 8 Electric A push button is in the wrong state during the version
System Error message display.
Action: Check Buttons & Cycle Power. If error persists call
service
Watchdog Watchdog Error 9 PLC System The Watchdog Timer has elapsed without being serviced.
Error Action: Cycle Power. If error persists call service
No Tach Impuls Error10 Electric The Machine Tachometer is reading a velocity outside of the
System Error range 10 – 230 meters per minute, while the main drive
should be running.
Action: Check the electric. If error persists call service.
Overload Uberlast Error11 Electric A Thermal Overload has been tripped.
System Error Action: Check the electric. If error persists call service
Pile Err Spg. Uber Error12 Electric The Pile Safety Relay is stuck on or there is no power supply to
System Error the pile circuits.
Action: Check the condition of Relay 1 K1, Fuses F1 and F2,
and X18, then cycle Power. If error persists call service
Overrun Uberlauf Error13 Electric The Pile Table has moved past its safety stops.
System Error Action: Check the limit switches, pile table, and wiring. If error
persists call service
2nd Stat 2Station Error14 Electric The Emergency Stop, Wrong Sheet, and Thermal Overload
System Error sense circuits are all indicating failure. Likely cause is Second
Station connector problems.
Action: Check the Second Station Connector, connector X22,
and each individual circuit. If error persists call service
Suction Saugtakt Error15 Electric Short circuit on Suction controller.
System Error Action: Check the electric. If error persists call service
CLR Stop CLR Stop Error16 Electric Emergency Stop activated during power-up sequence
System Error
ERROR 17 ERROR 17 Error17 Electric Incorrect check-back signal received from K2 protective relay.
System Error Power-up sequence (Check-back contact)
ERROR 18 ERROR 18 Error18 Electric Incorrect check-back signal received from K2 protective relay.
System Error Shutdown sequence (Check-back contact)
Table 19. Run Time Fault Messages