Owner manual

TP10476-1 PAGE 34
6. System Messages and Run Messages
6.1 Power-Up Fault Messages
Messages that are displayed during power on self-test.
If PLC System Errors are shown in the display, call service.
English German Codes TYPE DESCRIPTION
88888 88888 88888 Information The controller is performing its lamp test.
MEM MEM MEM Information The controller is performing its RAM test.
TEST TEST TEST
all blank all blank all blank PLC System The display board is not functioning.
Error Action: Cycle power. If error persists, call service.
ID Fail ID Fail ID Fail PLC System System cannot recognize the controller board.
Error Action: Cycle Power, if error persists, call service.
Error 1 Error 1 Error 1 PLC System The RAM test has found a bad memory location.
Error Action: Cycle Power, if error persists, call service.
Error 2 Error 2 Error 2 PLC System The Pile Safety Relay is stuck on or there is no power supply
Error to the pile circuits.
Action: Check the condition of Relay 1 K1, Fuses F1 and F2, and
X18. Cycle Power, if error persists, call service.
Error 3 Error 3 Error 3 PLC System There is power in the Pile Drive when it is off.
Error Action: Check the condition of Relay 1 K1, Fuses F1 and F2, and
X18. Cycle Power, if error persists, call service.
Error 4 Error 4 Error 4 PLC System The 24VAC inputs have current before the Watchdog
Error relay has been activated.
Action: Check for stuck push buttons, faulty sensors, or loose
connectors.Cycle Power, if error persists, call service.
Error 5 Error 5 Error 5 PLC System The membrane switch panel has a key pressed
Error during the power on self-test.
Action: Cycle Power, if error persists, call service.
Error 6 Error 6 Error 6 PLC System The Watchdog sense circuit indicates Watchdog timer operational
Error before it has been started.
Action: Cycle Power, if error persists, call service.
Error 6.1 Error 6.1 Error 6.1 PLC System Incorrect software in Eprom. Check Eprom type and files.
Error
Table 18. Power Up Fault Messages