Owner manual

TP10476-1 PAGE 24
P30: Port 1 Inputs
P30 indicates Port 1 input status.
P31: Port 2 Inputs
P31 indicates Port 2 input staus
P32: Port 3 Inputs
P32 indicates Port 3 input status
P33: Port 4 Inputs
P33 indicates Port 4 input status
P34:Port 5 Inputs
P34 indicates Port 5 input status
P35: Port 1 Outputs
P35 indicates Port 1 output status
Table 5 Safety settings
# Function Operation Key Combin. Variable Displayed
P60 Drive start key delay Adjustable with 0 - 13 secs.
P61 K2 release time Adjustable mit RP2 Adjuster- K2 Delayed release (sec)
(large display)
+
P60: Drive Start Delay period (only when A02=0)
Entering the Drive Start Delay period for Station 1 (Settings: 0 to 13.0 sec.) ensures that the paper runs
smoothly after starting if there is any paper still inside the machine. (Station 1: approx. 0.6 sec.)
P61: Display of delayed release for the K2 guard (only when A02=0)
Adjuster for setting the K2 delayed release (Measuring time = 0 to 10 sec.). Adjust with the RP2 poti on the
SGM-3 board. Default setting = approx. 2.5 sec.
# Function Type Variable Displayed
P40 Mon. time for Knife 1 Variable function Input X26/1, P32.5 Time in milliseconds
P41 Mon. time for Knife 2 Variable function Input X26/2, P32.4 Time in milliseconds
P42 Folding station delivery Variable function Input X30/5, P34.3 Time in milliseconds
P43 Counting input Variable function Input X25/5, P32.7 Time in milliseconds
P44 Knife 1 strokes Variable function Input X26/2, P32.4 Time in milliseconds
P45 Knife 2 strokes Variable function Input X26/5, P32.2 Time in milliseconds
P40: Time: Knife 1
Knife 1: Light sensor cover time in milliseconds.
P41: Time: Knife 2
Knife 2: Light sensor cover time in milliseconds.
Table 6 Machine statistics