Owner manual

PAGE 23 TP10476-1
P23: Pause
This function is used to activate/deactivate a Pause counter. Select this parameter to display the period of time
for which the pause function was last engaged. It is not possible to feed in sheets when the Pause function is
activated.
P24: Network
Network is only displayed when "Network" is selected and enabled in the Service menu. Not available in
Software Version 100.300.
P25:Easy Mode
This function can only be used on machine types P-b20, C-b20, C-2020 and P-2020.
P26:Hardware and Firmware Version
Select this parameter to display the software installed in Service mode. The logic board type appears in the left
of the display. DCT displays a DCT 500 logic board.
P27:Machine Type
Select this parameter to view the Machine type specified in Service mode.
P28:Serial Port
Parameter setting in Service mode is displayed: dSp, nEt, Off
P30 Status Input Port 1
P30.1 P30.2 P30.3 P30.4 P30.5 P30.6 P30.7 P30.8
Pile Motor Function Pile Down Pile Stop Pile Up Compress. Compress. Drive Start
Energized Control K1 Button Button Button Stop Button Start Button Relay K3
P31 Status Input Port 2
P31.1 P31.2 P31.3 P31.4 P31.5 P31.6 P31.7 P31.8
Pile Sensor Double Pile Down Sheet Start Sheet Stop Thermal Wrong Sheet Emerg.Stop
Sheet Fault Limit Button Button Fault Fault Drive Stop
Button
P32 Status Input Port 3
P32.1 P32.2 P32.3 P32.4 P32.5 P32.6 P32.7 P32.8
Ergonomic Jam on Knife in Jam on Jam on Suction Delivery Count sensor
Pile Load Knife 3 Manual Mode Knife 2 Knife 1 Controller Count Input Suction
Eye fail Wheel
P33 Status Input Port 4
P33.1 N P33.2 P33.3 P33.4 P33.5 P33.6 P33.7 P33.8
Board select Board select Not used Not used Not used Not used Not used Not used
P34 Status Input Port 5
A34.1 A34.2 A34.3 A34.4 A34.5 A34.6 A34.7 A34.8
External Setup LT folding External K2 Checkback Emerg. stop Emerg. stop Machine
Mis-feed sht. Station 2 station device signal station guard open Emerg. stop
delivery protection activated
P35 Status Output Port 1
P35.1 P35.2 P35.3 P35.4 P35.5 P35.6 P35.7 P35.8
Not used Controller Relief Not used Pile down Pile up Drive Stop Pump
drive valve/Tremat active is active function start (K4)
release ON (K6) Relay (K5)
Table 4 Machine diagnostic mode parameters