Manual

Camera Link
®
Interface
Notice
Only the lower CameraLink
®
port is used for communication. The upper port is
reserved for future use.
Caution
When xing the CameraLink
®
cable with too much force the screws
might get damaged.
The maximum torque is 2.5 inch lbf [0.3 Nm].
CameraLink
®
Base Connector
Pin Signal Pin Signal Pin Signal
1 GND 10 CC2+ 19 X3+
2 X0- 11 CC3- 20 SERTC-
3 X1- 12 CC4+ 21 SERTFG+
4 X2- 13 GND 22 CC1+
5 XCLK- 14 GND 23 CC2-
6 X3- 15 X0+ 24 CC3+
7 SERTC+ 16 X1+ 25 CC4-
8 SERTFG- 17 X2+ 26 GND
9 CC1- 18 XCLK+
Camera Link
®
, Process Interfaces and Power Supply
Caution
A power supply with electrical isolation is required for proper operation
of the camera. Otherwise the device may be damaged!
Power Supply Process Interface
wire colors of the connecting cable
1
4
3
8
5
7 3
1
4
2
6
8
5
7 3
1
4
2
6
7
1 (bn) Power V
CC
1 (wh) Out 3 5 (gr) IO Power V
CC
3 (bu) GND 2 (bn) In 2 6 (pk) Out 1
4 (bk) NC 3 (gn) In 1 7 (bu) Out 2
4 (ye) IO GND 8 (rd) In 3
LED Signaling
2
1
Signal Meaning
1
green Power on
green / yellow ashing Readout active
2
green Conguration command processing
red (yellow on both) Transmitting
Heat Transmission
Caution
Provide adequate dissipation of heat, to ensure that the temperatures
does not exceed +60°C (+140°F).
The surface of the camera may be hot during operation and immediately
after use. Be careful when handling the camera and avoid contact over a
longer period.
T T
T: Housing temperature
measurement point
As there are numerous possibilities for installa-
tion, a specic method for proper heat dissipation
is not dened, but the following principles are
suggested:
Operate the cameras only in mounted condition
with a good heat conductor (e.g. aluminum)
Mounting in combination with forced convection
may provide proper heat dissipation
General Description
1
2
3
4
56
No. Description No. Description
1 (respective) lens mount 4 Digial-IO supply
2 Power Supply 5 CameraLink
®
Base socket
3 unused 6 Signaling-LED