5 Connecting Encoder
5.1 Connection between PC and encoder
To realize the simplest possible connection to the PC, the encoder is equipped with an RS232
interface. With this the encoder can be connected directly to the PC. If the transfer distance is
greater than 30 m, it is advisable to use the RS485 interface. In this case an interface
converter with an automatic directional switchover function is required on the PC (not included
in the delivery scope).
5.1.1 Encoder programming connection
To program the encoder via a PC, the wires TxD, RxD and GND must be connected as
follows.
Connection assignment
Encoder
Function
D-SUB connector,
37-pin
PC Connection
D-SUB, 9-pin
UB Pin 36 -
RxD Pin 35 Pin 3
GND Pin 37 Pin 5
TxD Pin 34 Pin 2
Jumper 4-6 and
Jumper 7-8
The encoder must also be connected to the power supply (UB/red and GND/blue) via the
device plug.
Accessories: Z 139.009 Programming cable
ProCam programming software
Manual on CD