User Manual

Manual_GXP6H_EN.doc 11/13 Baumer IVO GmbH & Co. KG
04.05.11 Villingen-Schwenningen, Germany
8 Contact description
8.1 Contact description for C-plug
D01, D01 Incoming long-distance bus (A1) galvanically
DI1, DI1 separated from remaining encoder electr.
GNDI Galvanically separated reference mass for incoming long-distance bus (A1).
Models without electrical isolation combined with GND.
UB Contacts for encoder supply incorporated
GNDB within the bus (A1), UB = 10...30 VDC. Current load max. 700 mA
D02, D02 Relaying long-distance bus (W1)
DI2, DI2
GND Reference mass for relaying long-distance bus (W1)
UB Contacts for encoder supply within bus
GNDB (W1), UB = 10 ... 30 VDC. Connected internally with UB/GND B from A1
PE Screening combined with encoder housing
RBST Recognition of further bus users
Open contact: Last user
Contact to GND: User X
8.2 Pin assignment for C-plug
1
2
3
4
5
6
7
8
9
1
2
3
4
5
6
7
8
9
Incoming interface Outgoing interface
(pin) (socket)
Pin Assignment Pin Assignment
1 D01 1 D02
2 D01 2 D02
3 DI1 3 DI2
4 DI1 4 DI2
5 GNDI 5 GND
6 PE 6 PE
7 UB 7 UB
8 GNDB 8 GNDB
9 9 RBST