11.2 Electrical data
Operating voltage V
S
Limits: +10 VDC to +30VDC
Reverse-protected yes
Ripple V
S
10% within the limits of V
S
Power consumption < 2 W
Current consumption
Average: < 170 mA
Peak (after switching on) < 180 mA
Connectors
Main connector DIN 45322, 6-pole, male
Interface connector DIN 45326, 8-pole, male
Output circuit
FLDM 170G... push-pull
normal state low
FLDM 170C... opto-isolated
switchable voltage maximum 40 V
Load resistance maximum 50 kOhm
Current load: max. 100 mA
Short-circuit protected yes
Output pulse length selectable 0.3 … 100ms
11.3 Pin assignment (looking at connector on Scatec)
Main connector DIN 45322, 6 pole, male
Interface connector DIN 45326, 8 pole, male
Pin Assignment
1 output signal +Vout
2 encoder input B (FLDM 170G...)
output signal -Vout (FLDM 170C...)
3 operating voltage +Vs
4 encoder GND
5 encoder input A
6 operating voltage GND (0V)
Pin Assignment
1 CAN_H
2 not connected
3 serial TxD (sensor)
4 CAN_L
5 serial RxD (sensor)
6 CAN_GND
7 serial GND
8 GND
3
4
2
1
5
6
6
4
1
2
3
5
7
8