Owner manual

User manual Scatec-10 / -15 28 / 44 Baumer Electric AG
Version 2011-03 www.baumer.com Frauenfeld, Switzerland
10.3.3 Menu C: Parameters [Parametrs]
Operational parameters are set in menu C. A detailed description of these parameters is given in section 9
Setting the operational parameters.
Submenus not applicable in the present setting will be skipped in the display!
With the sensor locked, no parameters can be changed while navigation is still possible. The sensor can
be unlocked in menu B. When trying to change a parameter of a locked Scatec, the message “input
locked” will show up as reminder.
The sensor will be locked again if no key is pressed for 30 minutes
Submenu values
Comments
C0:
Pulse Length
xx.x ms
Output pulse length in ms
value of output pulse length in milliseconds
C1:
RunDirection
0 = lead
1 = trail
Running direction of the copies
leading
trailing
C2:
Fp-Suppress
0 = off
1 = on
False pulse suppression
no false pulse suppression mode will be activated
a false pulse suppression mode as defined in [C3]
will be activated
C3:
Suppr.Mode
00 = dyn
01 = sync
02 = fixed
03 = reflx
False pulse suppression mode
dynamic
synchronous
fixed
retro-reflective foil only
C4:
Dead Time %
xxx
Dead time in percentage
value of dynamic dead time in percentage of the mean
interval between copies
C5:
Encodr Resol
x.xx mm
Encoder resolution in mm/pulse
value of encoder resolution in millimeters per
encoder pulse
C6:
Dead Path mm
xxx mm
Dead path in mm
value of synchronized dead path mm
C7:
Encoder A/B
0 = off
1 = on
Encoder A/B
only A-channel of encoder is used
A- and B-channels of encoder are used
C8:
Dead Time ms
xxx ms
Dead time in ms
value of fixed dead time in milliseconds
C9:
Pulse Delay
0 = off
1 = on
Output pulse delay
output pulse issued immediately after end of the edge
output pulse issued with delay relative to end of the
edge