User Manual
en_BA_U500_UR18_Gen2_IO-Link.docx  40/43  Baumer Electric AG 
04.04.2019/    Frauenfeld, Switzerland 
6.6.1  Device Temperature 
Parameter name 
Short Description 
Rights 
Unit / 
Allowed 
values 
Device Temperature Lifetime 
Histogram.Mode 
Standard means: Linear 
partition of the range into 
bins. 
ro 
Standard 
Device Temperature Lifetime 
Histogram Unit 
Indicates the unit 
ro 
°C, K, F 
Device Temperature Lifetime 
Histogram.RangeStart 
Defines, where the range 
starts. 
ro 
-40 
Device Temperature Lifetime 
Histogram.RangeEnd 
Defines, where the range 
ends. 
ro 
+120 
Device Temperature Lifetime 
Histogram.Nbr of Bins 
Number of bins 
ro 
16 
Device Temperature Lifetime 
Histogram Bin1 … 16 
Number of counts of each 
bin 
ro 
32 Bit for 
each bin 
6.6.2  Power Supply 
Parameter name 
Short Description 
Rights 
Unit / 
Allowed 
values 
Power Supply Voltage Lifetime 
Histogram.Mode 
Standard means: Linear 
partition of the range into 
bins. 
ro 
Standard 
Power Supply Voltage Lifetime 
Histogram.Unit 
Indicates the unit 
ro 
Volts 
Power Supply Voltage Lifetime 
Histogram.RangeStart 
Defines, where the range 
starts. 
ro 
0 
Power Supply Voltage Lifetime 
Histogram RangeEnd 
Defines, where the range 
ends. 
ro 
+48  
Power Supply Voltage Lifetime 
Histogram Nbr of Bins 
Number of bins 
ro 
16 
Power Supply Voltage Lifetime 
Histogram Bin1 … 16 
Number of counts of each 
bin 
ro 
32 Bit for 
each bin 










