Parameter name 
Short Description 
Rights 
Output Scale Distance at Analog 
Min 
Teach-in the distance, mapped 
to the lower analog output 
value 
wo 
Output Scale Distance at Analog 
Max 
Teach-in the distance, mapped 
to the upper analog output 
value 
wo 
6  Diagnosis 
In addition to solving the primary application, the simple evaluation of secondary data, such as temperature, 
supply voltage or operating time, allows for predictive maintenance and thus optimum machine availability. 
6.1  Device Status 
Parameter name 
Short Description 
Rights 
Unit / Allowed 
values 
Device Status 
Indicates if the sensor is 
working properly 
ro 
0=Device is OK 
2=Out of 
Specification 
4=Failure 
Detailed Device Status 
ro 
6.2  Device Temperature 
An integrated temperature sensor allows to track the internal temperature of the sensor. 
Please be aware that compared to the ambient temperature the indicated values are higher due to the 
internal heating of the sensor.  
The temperature may also vary due to mounting conditions and due to the electric load connected to the 
output.  
Parameter name 
Short Description 
Rights 
Unit / Allowed 
values 
Device Temperature Reset 
Resets the device 
temperature statistic 
wo 
Device Temperature.Current 
Internal temperature of the 
sensor 
ro 
Device Temperature.Resetable Min  
Minimal measured internal 
temperature of the sensor 
(Resetable) 
ro 
Device Temperature.Resetable Max  
Maximal measured internal 
temperature of the sensor 
(Resetable) 
ro 