User Manual

en_BA_U500_UR18_Gen2_IO-Link.docx 37/43 Baumer Electric AG
04.04.2019/ Frauenfeld, Switzerland
Parameter name
Short Description
Rights
Output Scale Distance at Analog
Min
Teach-in the distance, mapped
to the lower analog output
value
wo
Output Scale Distance at Analog
Max
Teach-in the distance, mapped
to the upper analog output
value
wo
6 Diagnosis
In addition to solving the primary application, the simple evaluation of secondary data, such as temperature,
supply voltage or operating time, allows for predictive maintenance and thus optimum machine availability.
6.1 Device Status
Parameter name
Short Description
Rights
Unit / Allowed
values
Device Status
Indicates if the sensor is
working properly
ro
0=Device is OK
2=Out of
Specification
4=Failure
Detailed Device Status
ro
6.2 Device Temperature
An integrated temperature sensor allows to track the internal temperature of the sensor.
Please be aware that compared to the ambient temperature the indicated values are higher due to the
internal heating of the sensor.
The temperature may also vary due to mounting conditions and due to the electric load connected to the
output.
Parameter name
Short Description
Rights
Unit / Allowed
values
Device Temperature Reset
Resets the device
temperature statistic
wo
Device Temperature.Current
Internal temperature of the
sensor
ro
Device Temperature.Resetable Min
Minimal measured internal
temperature of the sensor
(Resetable)
ro
Device Temperature.Resetable Max
Maximal measured internal
temperature of the sensor
(Resetable)
ro