User Manual
en_BA_U500_UR18_Gen2_IO-Link.docx  35/43  Baumer Electric AG 
04.04.2019/    Frauenfeld, Switzerland 
System Command (Teach 
Apply) 
wo 
System Command (Teach 
Cancel) 
wo 
5.2.1  Single Point / 1-Point Teach 
If the selected SSC is configured as Single Point mode ( Changing the mode is explained in section 4.3.2.1), 
following command sequence is required to teach-in SP1: 
Command sequence: 
-  Place object at desired switching distance 
-  Execute Teach SP1 to teach-in the distance 
-  Execute Teach Apply to store the setpoint 
By executing Teach Cancel the teach-in procedure can be canceled at any state, as long Teach Apply has 
not been used before. 
Figure 28 Single Point Teach, switching behavior 
.P, .R, .D types  
In this example, the hysteresis is configured to be 
right aligned (See 4.3.2.4 for more details regarding 
hysteresis alignment) 
Figure 29 Single Point Teach, switching behavior 
.R types 
For more detailed information about the reflector 
tolerance, see section 4.3.2.5. 
5.2.2  Window Teach 
If the selected SSC is configured to Window mode ( Changing the mode is explained in section 4.3.2.1), 
following command sequence can be applied to teach-in SP1 and SP2 
Command sequence: 
-  Place object at desired switching distance 
-  Execute Teach SP1 to teach-in the distance related to SP1 
-  Execute Teach SP2 to teach-in the distance related to SP2 
-  Execute Teach Apply to store the setpoint 
By executing Teach Cancel the teach-in procedure can be canceled at any state as long Teach Apply has not 
been used before. 