User Manual
en_BA_U500_UR18_Gen2_IO-Link.docx  32/43  Baumer Electric AG 
04.04.2019/    Frauenfeld, Switzerland 
between output switching 
behaviour and pin 
Inverted:Pin high, LED off 
On: Pin high, LED on 
LED Settings.Blue.Mode   
Switches the LED off, no 
change of other function 
rw 
On / Off 
Default: On 
If the LED mode is set 
-  On, the behaviour of the related LED is as described in Figure 26. 
-  Off, the LED is deactived except if the function Find Me is activated. (See section 3.2.2) 
-  Inverted, the LED behaviour is inverted to the definition in Figure 26. 
If the yellow LED is configured to work as alignment aid (only for the .R type), the LED indicates the strength 
of the received signal. The faster the flashing, the stronger the signal. 
4.8.2  Teach Mode (Local, by wire) 
For the local teach, 2 different teach methods are available – Xpert and Xpress. 
While the Xpert mode represents the standard teach method with 4 teach levels available, the Xpress mode 
allows to simplify the teach-in procedure significantly by reducing it to only one teach level. 
Also the number of actions required to teach-in the position is reduced to one single activation of qTeach or 
the ext. teach-in. 
Parameter name 
Short Description 
Rights 
Unit / Allowed 
values 
Teach Mode Settings.Local Teach 
Mode 
Selects the teach mode if 
more than one is available. 
Teach modes: 0: xPert: 
normal method, 1: xPress: 
simplified method 
rw 
xPert static, 
xPress static  
Default: xPert 
4.8.2.1  xPert Mode 
Available Teach Levels: 
-  Level 1:  1-Point Teach (Barriers: Including alginment aid)  
-  Level 2:  Window Teach / Scanning Range 
-  Level 3:  Output Logic of digital output 1 and output 2 
-  Level 4:  Factory reset 
For a more detailed description of the teach-in procedure, please refer to the assembly instruction. 
4.8.2.2  Xpress Mode 
Available Teach Levels: 
-  Level 1:  Simplified 1-Point Teach 
Teach-In Procedure: 
-  Place object at desired switching / reference distance 
-  Activate qTeach or ext. teach-in wire for >2 sec 
o  Green and blue LEDs flash 2 Hz 
-  Teach-In OK: Sensor goes into operating mode 
-  Teach-In NOK: All LEDs flash 8 Hz for 1 sec 