User Manual

en_BA_U500_UR18_Gen2_IO-Link.docx 30/43 Baumer Electric AG
04.04.2019/ Frauenfeld, Switzerland
4.7.3.3 Synchronization Input Mode (Sync-In.) Mode
Link the control pin of all sensors within a limited area to each other. This triggers the measurement of all
sensors at the same time. Interference signals which arrive later at the sensor due to their longer sensing
distance, will be ignored. Up to ten sensors can be synchronized via control pin.
Note: If the pin is not in use it must be connected to a defined potential to ensure the standard response
time:
Input Mode: Synchronization: Connect the control pin to supply voltage (+Vs)
Input Mode: Multiplex: Connect the control pin to ground (GND)
Input Mode: Teach-In
4.7.3.4 IO-Link triggered
Use this mode to syncronize the sensors via the Process Data-Out Channel (see section 3.2.2 for the
process data-out structure, below you can find the structure as well). As long as Bit 2 is high (e.g. 1) the
sensor measures for only one measurement cycle. When the bit is set to 0 the sensor will not measure and
represent the last measured value on the output pin and in the Process Data-In Channel.
IO-Link Process Data Output
Bit:
7
6
5
4
3
2
1
0
Trigger
Find Me (Localization: LEDs
flashing)
Disable
Transducer
When to use?
This way of syncronisation is very beneficial in order to reduce the wiring costs. Compared to the other
syncronisation options no extra cable is needed.