User Manual
en_BA_U500_UR18_Gen2_IO-Link.docx  25/43  Baumer Electric AG 
04.04.2019/    Frauenfeld, Switzerland 
4.4.2  Sonic Cone Adjustment 
Via this parameter the width of the sonic cone is modified. This is useful to measure reflections from weak 
reflections objects (setting “wide”) or to measure through narrow openings (setting “narrow”).  
Parameter name 
Short Description 
Rights 
Unit / Allowed values 
Beam Forming.Sonic 
Cone Adjustment 
Set the width of the sonic cone 
rw 
-  narrow 
-  medium (Default) 
-  wide 
Figure 2: Sonic cone Input Mode adjustment 
4.4.3  Disruption Filter 
This filter allows you to ignore interfering objects when passing through the measuring range either cyclic or 
non-cyclic. This function depends on two parameter 
Parameter name 
Short Description 
Rights 
Unit / Allowed values 
Process Value 
Disruption 
Filter.Maximum 
perturbation time 
Duration (in units of time) until a signal (as 
defined in the parameter . Distance) 
becomes visible at the output. 
rw 
Limits: 0 to 10.000ms 
Default: 24ms 
Process Value 
Disruption 
Filter.Distance 
Distance deviations from the current 
measured value which are ignored, if 
shorter than the period set by the 
parameter '. Maximum perturbation time. 
rw 
Limits 5mm to 1000mm, 
Default: 50 mm 