User Manual

en_BA_U500_UR18_Gen2_IO-Link.docx 25/43 Baumer Electric AG
04.04.2019/ Frauenfeld, Switzerland
4.4.2 Sonic Cone Adjustment
Via this parameter the width of the sonic cone is modified. This is useful to measure reflections from weak
reflections objects (setting “wide”) or to measure through narrow openings (setting “narrow”).
Parameter name
Short Description
Rights
Unit / Allowed values
Beam Forming.Sonic
Cone Adjustment
Set the width of the sonic cone
rw
- narrow
- medium (Default)
- wide
Figure 2: Sonic cone Input Mode adjustment
4.4.3 Disruption Filter
This filter allows you to ignore interfering objects when passing through the measuring range either cyclic or
non-cyclic. This function depends on two parameter
Parameter name
Short Description
Rights
Unit / Allowed values
Process Value
Disruption
Filter.Maximum
perturbation time
Duration (in units of time) until a signal (as
defined in the parameter . Distance)
becomes visible at the output.
rw
Limits: 0 to 10.000ms
Default: 24ms
Process Value
Disruption
Filter.Distance
Distance deviations from the current
measured value which are ignored, if
shorter than the period set by the
parameter '. Maximum perturbation time.
rw
Limits 5mm to 1000mm,
Default: 50 mm