User Manual
en_BA_U500_UR18_Gen2_IO-Link.docx  22/43  Baumer Electric AG 
04.04.2019/    Frauenfeld, Switzerland 
4.3.4  Counter / SSC4 
For each individual SSC a switching counter is implemented, which can be used as diagnosis data or also as 
measurement value. The number of counts of each channel can also be mapped to the measurement data 
channel MDC by adjusting the MDC source (See section 0). 
Trigger of counter is on positive slope of related SSC. 
By configuring SSC4, it is also possible to set up a binary signal related to the number of switchcounts of 
SSC1 or SSC2. An auto-reset and timefilters are included, to be able to create a full-featured counter being 
able to count lot sizes without any need to code software on the PLC.  
As all SSCs, SSC4 can also be mapped to the digital output giving the possibility to create a stand-alone lot-
size counter. 
In section 3.1, the signal path is decribed more detailed, to illustrate how the counter module is implemented. 
In section 4.3.4.2 the behavior depending on the configuration is explained. 
4.3.4.1  SSC4 Configuration 
In general the SSC4 offers the same features as the SSC1 and SSC2 based on distance (See 4.3.2), 
including also timefilters. 
Exceptions: 
-  No hysteresis settings as there are only incremental counts. 
-  Additional parameters to adjust like SSC4 Source and SSC4 Auto-Reset. 
Parameter name 
Short Description 
Rights 
Unit / Allowed values 
SSC4 Param.SP1 
Set the number of counts at which the 
SSC is set to active (or inactive if 
inverted) 
rw 
0 … max = 2147483639 
Counts, default 20 
SSC4 Param.SP2 
Set the number of counts at at which the 
SSC is set to inactive (or active if 
inverted). only active if SSC is set to 
window mode 
rw 
0 … max = 2147483639 
Counts, default 0  
Parameter name 
Short Description 
Rights 
Unit / Allowed values 
SSC4 Config.Logic 
Selects the SSC logic. It can be 
changed between active if object 
is present (normal) or inactive if 
object is present (inverted) 
rw 
-  Normal (Default) 
-  Inverted 
SSC4 Config.Mode 
Selection of the switching mode 
rw 
-  Disabled 
-  Single Point (Default) 
-  Window 
SSC Source 
Settings.SSC4 Selection 
Select the switch counter that is 
used as input of SSC4 
rw 
-  SSC1 Switch Counter 
(Default) 
-  SSC2 Switch Counter 
SSC Source 
Settings.SSC4 Auto 
Reset 
Auto Reset of switch counter if 
value in SSC4 Param.SP1 is 
reached 
rw 
-  Enabled (Default) 
-  Disabled 