4.3.2.4.1  Left Aligned 
Left Aligned defines the hysteresis to be aligned towards the sensor / against the sensing direction. 
When to apply? 
-  For an accurate switching distance in case the object is moving away from the sensor 
o  Example: Detection of the low level of a tank to avoid a dry-run 
Figure 12 Left Aligned, Single Point Mode 
Figure 13 Left Aligned, Window Mode 
4.3.2.4.2  Right Aligned 
Right Aligned defines the hysteresis to be aligned away from the sensor / in sensing direction. 
When to apply? 
-  For an accurate switching distance in case the object is moving towards the sensor. 
o  Example: Stop trigger application, usual detection tasks. 
Figure 14 Right Aligned, Single Point Mode 
Figure 15 Right Aligned, Window Mode 