User Manual

en_BA_U500_UR18_Gen2_IO-Link.docx 16/43 Baumer Electric AG
04.04.2019/ Frauenfeld, Switzerland
4.3.2.4.1 Left Aligned
Left Aligned defines the hysteresis to be aligned towards the sensor / against the sensing direction.
When to apply?
- For an accurate switching distance in case the object is moving away from the sensor
o Example: Detection of the low level of a tank to avoid a dry-run
Figure 12 Left Aligned, Single Point Mode
Figure 13 Left Aligned, Window Mode
4.3.2.4.2 Right Aligned
Right Aligned defines the hysteresis to be aligned away from the sensor / in sensing direction.
When to apply?
- For an accurate switching distance in case the object is moving towards the sensor.
o Example: Stop trigger application, usual detection tasks.
Figure 14 Right Aligned, Single Point Mode
Figure 15 Right Aligned, Window Mode