4.2.3 MDC Source
Selects which measuring value is mapped to the MDC channel and is then available via the process data-IN
path. When SSC1, SSC2 or SSC4 is selected the number of switches detected by the channel is shown.
Parameter name
Short Description
Rights
Unit / Allowed values
MDC Selection.Source
Select the process value that is
shown on the MDC channel
ro
- Distance (Default)
- Switch Counter SSC1
- Switch Counter SSC2
- Switch Counter SSC4
4.2.4 MDC Unit Code
Parameter name
Short Description
Rights
Unit / Allowed values
MDC Descriptor.Unit
code
Indicates the unit of the selected
MDC source
ro
4.2.5 MDC Setpoint limit
This parameter allows to read out the limits of the measuring range of the sensor.
Parameter name
Short Description
Rights
Unit / Allowed values
MDC Descriptor.Lower
limit
Lower value of measuring range, if
value is below out of range is
shown
ro
A0: 50 mm
MDC Descriptor.Upper
limit
Upper value of measuring range, if
value is above out of range is
shown
ro
A0: 1500 mm