User Manual

Baumer_GIM500R_Analog_MA_EN.docx 17/20 Baumer IVO GmbH & Co. KG
11.04.18 Villingen-Schwenningen, Germany
3.6 Restore Factory Settings
3.6.1 How to Restore Factory Settings
Action
LED
indication
Description
Initial situation
LED is green continuous
Activate
> 15 ms
Set teach input on HIGH for >15 seconds.
DUO-LED: amber flashing after 5 seconds
End operation
Set teach input to LOW.
DUO-LED: Amber continuous for 3 seconds
Operational mode
DUO-LED: indicates the present status, operational/
non-operational
3.6.2 Time pattern of Restore Factory Settings
0
1
2
3
4
5
20
21
22
23
6
7
8
9
10
11
12
13
14
15
16
17
18
19
DUO-LED
HIGH
LOW
Teach-input
U