Datasheet

www.baumer.com/motion
Incremental encoders
5
Subject to modication in technic and design. Errors and omissions excepted.7/1/2019
EIL580P-SC - OptoPulse
®
Solid shaft with clamping ange
1…65536 pulses per revolution programmable (interpolated system)
The duty cycle (D) is dened as the time ratio between the
HIGH pulse duration (H) and the pulse period (T).
System-induced and depending on the pulse number, the
measured values may vary which has an impact on speed
and position acquisition.
Binary pulse numbers are recommended for speed feed-
back.
Programmed
pulse number
Scan ratio (D)
(maximum)
Jitter (+/-)
(maximum)
1…1023 45...55 % 5%
1024, 2048 45...55 % 5%
1025…5000 40...60 % 10%
8192, 16384 35...85 % 15%
5001…10000 22...78 % 28%
32768 25...75 % 25%
65536 15...85 % 35%
all other Jitter[%]=(programmed pulse
number -10000)*0,0007%+28%
D =
HIGH-part (H)
Pulse-period (T)
H
T
Duty cycle