Datasheet
www.baumer.com/motion
Incremental encoders
5
Subject to modication in technic and design. Errors and omissions excepted.7/1/2019
EIL580P-SC - OptoPulse
®
Solid shaft with clamping ange
1…65536 pulses per revolution programmable (interpolated system)
The duty cycle (D) is dened as the time ratio between the
HIGH pulse duration (H) and the pulse period (T).
System-induced and depending on the pulse number, the
measured values may vary which has an impact on speed
and position acquisition.
Binary pulse numbers are recommended for speed feed-
back.
Programmed
pulse number
Scan ratio (D)
(maximum)
Jitter (+/-)
(maximum)
1…1023 45...55 % 5%
1024, 2048 45...55 % 5%
1025…5000 40...60 % 10%
8192, 16384 35...85 % 15%
5001…10000 22...78 % 28%
32768 25...75 % 25%
65536 15...85 % 35%
all other Jitter[%]=(programmed pulse
number -10000)*0,0007%+28%
D =
HIGH-part (H)
Pulse-period (T)
H
T
Duty cycle