User Manual
INSTALLATION 
The installation must be carried out by a suitably 
qualified person, in accordance with the current 
version of the following. 
o  UK Regulations and Safety Standards or their European 
Norm Replacements. 
o  Building Regulations  (issued by the Department of the 
Environment). 
o  Building Standards (issued by the Scottish Development 
Department). 
o  IEE Wiring Regulations. 
o  Electricity At Work Regulations. 
Before connecting the appliance, make sure that the supply voltage 
marked on the rating plate corresponds with your mains supply 
voltage. 
WARNING: THIS APPLIANCE MUST BE EARTHED. 
o  This appliance should be wired into a 13A double pole switched 
fused spur outlet, having 3 mm contact separation and placed in 
an easily accessible position adjacent to the appliance. The spur 
outlet must still be accessible even when your oven is located in 
its housing. 
o  To connect the oven power cord, loosen and remove the cover 
on the terminal block, in order to gain access to the contacts 
inside. Make the connection, securing the cord in place with the 
cable clamp provided and then immediately close the terminal 
block cover again. 
o  If you have to change the oven power cord, the earthing 
(yellow/green) conductor must always be 10 mm longer than the 
line conductors. 
o  Care must be taken to ensure that the temperature of the mains 
supply cable does not exceed 50°C. 
o  If the mains supply cable is damaged, then it must be replaced 
by an appropriate replacement which can be obtained from the 
Baumatic Spares Department. 
29