Gas adjustment (Conversion to LPG for the hob top)
All work must be carried out by a GASSAFE
registered engineer.
IMPORTANT: Always isolate the cooker from the electricity
supply before changing the injectors and/or adjusting the
minimum flow of the burners.
o Remove the pan-stands, burners and flame
spreaders (A).
34
o Unscrew the injector (B) and replace it with the
stipulated injector for the new gas supply (see table
below).
o Reassemble all the burners carefully; in particular you should
make sure that the flame spreader is correctly placed on the
burner.
IMPORTANT: After changing the injectors YOU MUST follow the
inimum flow adjustment section below. m
OPERATING
P RERESSU GAS
RATE DIAMETER
INJECTOR
HEAT
INPUT
BY-PASS
BURNERS
GAS MBAR
g/h
L/h
1/100 mm MIN MAX 1/100
mm
LPG -
Butane
28-30 218
88 800 3000
LPG -
Propane
37 214
88 800 3000
Rapid
Natural 20 286
1 17-Y 800 3000
44
LPG -
Butane
28-30 131
68 600 1800
LPG -
Propane
37 129
68 600 1800
Semi-rapid
Natural 20 171
9 8-Z 600 1800
34
LPG -
Butane
28-30 73 51 400 1000
LPG -
Propane
37 71 51 400 1000
Auxiliary
Natural 20 95 7 5-X 400 1000
28