6. ELECTRONIC SETTINGS (Cont’d)
Trigger De-Bounce (Solid Amber): Default 5 blinks = 5ms
This setting helps to minimize Trigger “bounce” that may cause unwanted shots/ Trigger
pulls. A higher setting will reduce the bounce. A lower setting will allow for more bounce.
1 blink corresponds to 1ms of De-Bounce time. De-Bounce is adjustable from 1-15ms.
Ball In Place Delay (Solid Aqua): Default 5 blinks = 5ms
This setting controls how long after the Break Beam Eye system detects an object that the
marker will wait before it is allowed to fire. A lower setting can help achieve higher rates of
fire. A higher setting is recommended to prevent ball breakage. 1 blink corresponds to 1ms
of delay. BIP is adjustable from 1-40 blinks (1-40ms).
Ramp Start (Solid Purple): Default 3 blinks = 3 shots
This setting controls the amount of semi-automatic shots must be fired before ramping will
start. If the marker is not fired for 1 second, the count will reset. 1 blink corresponds to 1
shot. Ramp Start can be varied from 3– 12 blinks (3-12 shots).
Ramp Sustain (Solid White): Default 3 blinks = 3tps
This setting controls the amount of Trigger pulls per second (TPS) that must be achieved
and sustained for ramp to kick in. 1 blink corresponds for 1 Trigger pull per second. Ramp
Sustain can be varied from 1-12 blinks (1-12tps).
Note: This setting affects only Ramp Firing Mode.
Burst Shots Count (Flickering Red): Default 3 blinks = 3 shots per Trigger pull
This setting controls the amount of shots that are fired on each Trigger pull when the Burst
Firing Mode is being used. 1 blink corresponds to 1 shot. The Burst Shot Count can be varied
from 2 to 6 shots.
Note: This setting only affects Burst Firing Mode.
Calibrate Sensor (Flickering Green): Default Not Applicable
Selecting this will put the electronics in a mode to calibrate the mode Selector Switch sensor.
Each mode Selector Switch is calibrated from the factory. Should the user switch circuit
boards or if the mode Selector Switch is not working properly the Selector Switch may need
to be calibrated.
How To Calibrate: When calibrate sensor mode is activated the LED will shine Aqua.
Step 1. Move Selector to Safe Position.
Step 2. Press and release Trigger, the LED will turn Green indicating a reading is
being taken.
Step 3. When the LED turns Aqua, move the selector to position (red) 1.
Step 4. Press and release Trigger, the LED will turn Green indicating a reading is
being taken.
Step 5. When the LED turns Aqua again, move the selector to position (red) 2.
Step 6. Press and release Trigger, the LED will turn Green indicating a reading is
being taken.
Step 7. When the LED turns Aqua again, move the selector to position (red) 3.
Step 8. Press and release Trigger, the LED will turn Green indicating a reading is
being taken.
If the board blinks Red at the end of taking all 4 readings it means that there was an error and
calibration should be attempted again. Otherwise the board will shut down and the LED’s
will turn off.