SIMPLIFIED OPERATING INSTRUCTIONS
Read and thoroughly understand ALL SAFETY Instructions, pages
3 - 7 including Preparing to Charge, DC Connection Precautions,
Unit Location and Qualifying Your Battery BEFORE proceeding
further.
1. Attach Battery Clips (7) (supplied), to output cordset of charger (4).
2. Attach output to battery terminals:
RED band = Positive +
BLACK band = Negative -.
3. Ambient Temperature Sensor, ATS-1 (8), comes already installed on
the Temperature Sensor input connector (3). Do not detach. The
Ambient Temperature Sensor (ATS-1) is mandatory when used
with all Aviation batteries.
4. Plug AC power cord (5) into a 220 - 240 Vac electrical outlet.
5. Observe Reversed Polarity GREEN/RED LED indicator (1a):
If lit RED, reverse battery connector attachments on battery.
6. Observe Charging - Maintenance/Desulfating GREEN LED
indicator (1c):
Solid = charging
Blinking = maintaining battery(s).
Charger will automatically start within 30 seconds or less.
7. Observe Battery Connected - Error LED Indicator (1a):
Must be lit GREEN
1
.
Be sure Maintaining - Desulfating LED (1c)
is BLINKING before leaving
unit for an extended period of time. Otherwise, press & hold the
Maintenance button (2) for 3 seconds.
IF IN DOUBT REGARDING ANY OF THE ABOVE, REFER TO Detailed
Operating Instructions, page 12.
1
See full instructions if not lit GREEN.