The chart below shows the need to regulate the output voltage of the unit to ensure against over or under charging your
battery over a wide range of temperatures. Using your At-the-Battery Sensor will accomplish this better than any other known
method. Please note: Table is for STANDARD AVIATION setting. The GILL 7000 SERIES, ODYSSEY and HAWKER
setting provides charging voltage of 29.4V and float of 27.2V at 25°C/77°F. The CONCORDE setting provides charging
voltage of 28.2V and float of 27.0V at 25°C/77°F. All settings are properly temperature compensated.
AGM and Flooded (wet-cell) Charge and Float Voltages at Various Temperature Ranges**
Temp °F
Optimum Charge
Optimum Float
Temp °C
≥ 120
26.80
24.90
≥49
110 – 120
27.20
25.10
43 – 49
100 -110
27.40
25.30
38 – 43
90 – 100
27.60
25.50
32 – 38
80 – 90
27.80
25.70
27 – 32
70 – 80
28.20
26.10
21 – 27
60 – 70
28.50
26.60
16 - 21
50 – 60
28.80
27.00
10 - 16
40 – 50
29.20
27.40
4 - 10
≤ 40
29.80
27.80
≤4