BatteryMINDer® Model 28252-AA-Series (With Desulfation) INSTRUCTION MANUAL 28-Volt @ 25 Amp Avionic Power Supply / Charger Desulfator FOR 24-V LEAD-ACID AIRCRAFT BATTERY ONLY. Contact VDC Electronics for any other resets needed Dip Switch Settings Standard Aviation 1 2 5 Concorde Aviation Gill 7000 Series, Odyssey & Hawker 8 1 2 5 8 1 2 5 8 VDC Electronics, Inc. 147D Woodbury Road Huntington, NY 11743 U.S.A. www.BatteryMINDers.
BatteryMINDer® Model 28252-AA-Series TABLE OF CONTENTS Cautions and Features 4 Required Safety Instructions 6 Never Charge a Frozen Battery 7 Unit Location 7 DC Connection Precautions 7 A Spark Near the Battery May Cause Battery Explosion 8 Testing a Filler Cap Lead Acid Battery 9 Qualifying Your Battery 9 - 10 Specific Gravity – Capacity 10 Testing a Sealed, AGM, Lead Acid Battery 11 Use a Digital Voltmeter Only 11 Open Circuit No Load Voltage Table 11 Operating Instructions (Simp
BatteryMINDer® Model 28252-AA-Series TABLE OF CONTENTS (con’t.) Power Supply Mode Selected Table Safety and Protection Table 28 28 Electrical Cable and Physical Parameters 29 Desulfator Wave 30 Top View and Dimensions 31 LED Aviation Display Table 32 Your Notes 33 Repair or Replacement (US & Canada) 34 Repair or Replacement (Outside US & Canada) 35 Warranty 36 Rev.
BatteryMINDer® Model 28252-AA-Series CAUTIONS: READ AND FULLY UNDERSTAND BEFORE OPERATING. Contact VDC Electronics if uncertain about any settings or operation.
BatteryMINDer® Model 28252-AA-Series • Displays charging current, voltage, charging time, charging AH, output power, battery temperature. • Displays function settings: Power supply, Charge, Maintenance, Desulfation. • Dip switch resets for different transition current and charging voltage levels. • Detachable AC input cord receptacle for IEC world wide safety approved cord sets. • 14’ DC output cable with Heavy duty Anderson connector. • AC On / Off power switch Plug ‘n Run simplified operation.
BatteryMINDer® Model 28252-AA-Series REQUIRED SAFETY INSTRUCTIONS WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TOPERSON, OBSERVE THE FOLLOWING: • This unit is designed for protected use and should never be exposed to rain. • Do not attempt to use the unit if it has been dropped or damaged. • Never attempt to charge a damaged battery, frozen battery or nonrechargeable battery. • Do not use the unit in a closed area or poorly-ventilated area.
BatteryMINDer® Model 28252-AA-Series Always follow battery manufacturer’s strict instructions for proper care, charging and testing of battery. Always use their FAA Approved “Instructions for Continued Airworthiness” (ICA). Questions relating to the subject should be referred directly to the battery manufacturer to be certain of current requirements that may have been added to or changed since publication of their instructions. NEVER CHARGE A FROZEN BATTERY OR ONE AT A TEMPERATURE ABOVE 123° F.
BatteryMINDer® Model 28252-AA-Series UNIT LOCATION A SPARK NEAR THE BATTERY MAY CAUSE BATTERY EXPLOSION. TO REDUCE RISK OF A SPARK NEAR BATTERY: a. Connect (RED) charger clip to (POS+) post of battery. b. Position yourself and free end of cable as far away from battery as possible, then connect NEGATIVE (BLACK) charger clip to free end of cable. c. Do not face battery when making final connections. d.
BatteryMINDer® Model 28252-AA-Series QUALIFYING YOUR BATTERY: Preliminary Requirements NOTE: The BatteryMINDer has no electrical output unless it is connected to a healthy battery. Testing the BatteryMINDer with a volt or an Amp meter without the unit being connected across a good battery will result in a false reading. If you experience any problems, or are not sure of how to properly use or connect your BatteryMINDer, please e-mail our Tech Support Dept. at: techsupport@vdcelectronics.
BatteryMINDer® Model 28252-AA-Series be thoroughly familiar with the safety and operating instructions. 4. Recharge the battery with the BatteryMINDer to ensure that it is slowly and completely charged before you determine its condition. Allow battery to “rest”* overnight or momentarily apply a small load to remove the “surface” charge which creates false voltage readings. * “RESTED” = a battery that has been as fully charged as possible and left disconnected from charger or any type load overnight.
BatteryMINDer® Model 28252-AA-Series TESTING A SEALED, AGM LEAD ACID BATTERY These batteries have no filler caps or manifold-type covers. Because you cannot gain access to the interior of your battery you cannot test it with a hydrometer. USE A DIGITAL VOLTMETER ONLY: 1. Recharge the battery with the BatteryMINDer to ensure it is as completely charged as possible, before you determine its condition. Allow battery to “rest” (see pg. 9) overnight before testing with a digital voltmeter only.
BatteryMINDer® Model 28252-AA-Series Simplified Operating Instructions The BatteryMINDer has no electrical output unless it is connected to a battery with a minimum of 6-Volts or when in Power Supply Mode. • Attach Temperature/Voltage Sensor to TempSensor Receptacle A and Ring Terminal to positive Battery Terminal. • Attach Battery Connector Attachments (BCA) to DC-CORD Output of unit. • Plug AC Power Cord into 95 - 240 Vac electrical outlet. Turn AC POWER Switch On.
Rev.
BatteryMINDer® Model 28252-AA-Series Included & Optional Battery Connectors BC 2410 Battery Clips (included) A2RT 11/32” Ring Terminals (optional) A2GPU-1 Anderson SB-50 to Cessna style GPU Plug (optional) ABS-2825 Temperature/Voltage Sensor (At-the-Battery Sensor) (included) A2ELCON ELCON Type Connector (optional) *Must be used on aircraft where a relay needs to be activated in order to connect the battery and GPU. Rev.
BatteryMINDer® Model 28252-AA-Series When using the Temperature Sensor at any location (other then on a battery) the ring terminal must be insulated, heat shrink tubing is recommended. If using the A2GPU-1 or A2GPU2 and are unable to place the Temperature Sensor on a battery terminal, it may be inserted into the unused cavity of the A2GPU plug and secured with cable clamp. A2GPU-1 Plug Instructions 1. Connect A2GPU 2. Turn on 28252 3. Hold down “Power Supply/Charge” for 5 seconds and release 4.
BatteryMINDer® Model 28252-AA-Series OPERATING INSTRUCTIONS 1. Pre-Charge Check (a) Check the Battery Electrolyte level (Non-sealed Batteries). If necessary, remove the vent caps and add distilled water so levels are halfway between the upper and lower fill lines. (b) Location – Ensure the Battery is in a well ventilated area. Keep the Unit as far away from Battery as the cables permit.
BatteryMINDer® Model 28252-AA-Series 3. Aviation charge mode connection (1). Connect to 24V Aviation battery. (2). You MUST connect Temperature/Voltage Sensor ABS-2825 (no substitute) to the Positive (+) battery terminal. (3). Connect the output DC cable RED clips to the battery Positive polarity (+), the BLACK clips to the battery Negative polarity (-). 4. Connect the unit to AC input power Turn on the AC power switch.
BatteryMINDer® Model 28252-AA-Series 5. The Charging Process The Charging LED’s will indicate the Charging Stages. LCD will display the values and functional setting. The charging stages are as follows: • Soft Start: Charges the battery using half the maximum current until the battery voltage is over 22V (indicated by YELLOW Bulk LED FLASHING).
BatteryMINDer® Model 28252-AA-Series To Change the Mode on the BatteryMINDer 28252-AA-Series: • After the unit is powered on, if you do not press a Mode Button within 30 seconds, you will need to press the Mode Button TWICE • If the unit has not had a Mode changed within 30 seconds, you will need to press the Mode Button TWICE In each instance, you only need to press the Mode Button ONCE if done within 30 seconds after the previous operation This is a safety feature to help prevent inadvertent operations,
Rev.
BatteryMINDer® Model 28252-AA-Series Temperature has a direct effect on the life of a battery. The design life of the battery is based on an average annual temperature of 25°C (77°F). As the temperature increases above 25°C (77°F), the life of the battery decreases. The chart below shows the effects of temperature.
Rev. I-100511 27.20 27.40 27.60 27.80 28.20 28.50 28.80 29.20 29.80 100 -110 90 – 100 80 – 90 70 – 80 60 – 70 50 – 60 40 – 50 ≤ 40 26.80 ≥ 120 110 – 120 Optimum Charge Temp °F Page 22 27.80 27.40 27.00 26.60 26.10 25.70 25.50 25.30 25.10 24.
Error LED is ON. LCD displays E01 Error LED is Flashing and Battery is severely sulfated LCD displays E04 Battery has a damaged cell Battery aged LCD displays E05 or E06 Fault LED is Flashing LCD displays E02, E03 or E04 Error LED Flash, LCD meter displays normally ALL LED’s continuously or intermittently Flash Unit has no DC output No Charging Current Stop charging during charging progress Rev.
BatteryMINDer® Model 28252-AA-Series DETAILED SPECIFICATIONS (R12) VDC Model No. 28252-AA-Series 24-V 25 Amp H.F. Battery Charger/ Desulfator/ Power supply Program Code No.: 28252-r0.8 Battery Type: 24V Lead-acid Aviation Sealed or Flooded Battery Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
Rev. I-100511 Page 25 >85% 100 6.6 NORMAL 100-240 50/60 max.
Rev. I-100511 Battery voltage is between 6-22 6.25 Battery voltage is above 22 6 Battery voltage is above 22 25 Soft start charging activity conditions: Soft start charging output current control: Soft start mode transits to bulk mode: Soft start charging time limit: stops charging Bulk charging condition: Bulk charging current control: Page 26 15 Battery voltage above 28.21 Battery voltage is constant at 28.2 12 Max.
Rev. I-100511 4 Battery voltage is maintained at 25.8 ~ 26.11 5 Battery voltage is below 25.2 Max Equalizing Time: Float charging output voltage control: Max. Float charging current control Restarts Bulk charging when battery voltage is low: Page 27 3 Max. flow back current (to unit) when connected to battery, AC power disconnected max. max. max.
Rev. I-100511 Page 28 1000.0 0.10 Desulfation output PWM frequency Desulfation duty Hz % Adc UNIT UNIT Vdc Adc Vdc SAFETY & PROTECTION Safety Standards: EMC Standards: Input-Output insulation test : Cooling: Built-in temperature protected Output short-circuit, reverse polarity Protection UL-1236, EN60335-1. EN60335-2-29 FCC-Part 15 Class B; EN55014 3000Vac 50/60Hz with 1 minutes, 5mAac By Fan forced air - Temperature Sensing Voltage is for STANDARD AVIATION setting.
Rev. I-100511 Page 29 0 to 90% RH -10°C/14°F to 40°C/104°F 250V 15A IEC socket SJT VW-1 105°C 16AWG 3C with 3PIN UL plug, 6 feet external length. ON/OFF power switch 50A anderson connector 14’ long output cord with Anderson Plugs on both ends 12” long cord with 50A Anderson Plug and battery clips 240 (L) x 215 (W) x 97 (H) mm / 9.45 x 8.46 x 3.8 in Storage -25°C/77°F to 85°C/185°F temperature: Weight: 3.5 Kg / 7.7 lbs. approx. THDI<=5% (Total Harmonic Distortion of Current) PowerFactor (PF) =0.
Rev. I-100511 Page 30 Bulk 25A Absorption * Soft start 6.25A 28.2 - 29.4V Equalizing Current limited 30.0 - 32.0V Float Maintenance current 25.8~27.2V * * * Depending on model Remarks: If power fails and then resumes, unit will automatically start from initial charging cycle. Voltage Current 22.
7.0” 177.8 mm Rev. I-100511 3.5” 88.9 mm 9.45” 240.0 mm 8.46” 214.
Rev. I-100511 Page 32 ON OFF OFF OFF OFF OFF OFF OFF OFF OFF ON ON ON ON ON ON ON ON ON ON Bulk charging Absorption charging Equalization charging Float charging Output clips shorted or battery polarity is reversed Soft start charging 6 hours timed out Bulk charging 15 hours timed out Charger internal over-temperature protected Manual desulfation Power Supply mode Display: Aviation on LCD FLASH ON Soft start charging Aviation charging mode selected OFF ON YELLOW GREEN A.C.
BatteryMINDer® Model 28252-AA-Series YOUR NOTES: Rev.
BatteryMINDer® Model 28252-AA-Series FOR REPAIR OR REPLACEMENT US and Canadian Residents All returns must be authorized by VDC Electronics. In the event that you believe your product may be defective, you MUST speak to a VDC Electronics technician at 1-800-379-5579 x206 (ET) before proceeding further. If after speaking with our tech support personnel it is necessary to return the unit, you MUST request an RMA number.
BatteryMINDer® Model 28252-AA-Series FOR REPAIR OR REPLACEMENT (Outside US & Canada) In the event that you believe your product may be defective, you MUST contact a VDC Electronics technician at techsupport@ vdcelectronics.com. We will advise you on the best way to proceed. Please do not return your product to us without our authorization. Note: If your questions relate to safety concerns, please contact: billwoods@vdcelectronics.
BatteryMINDer® Model 28252-AA-Series ALL returns must be authorized by VDC Electronics after speaking to a VDC Electronics technician at 800-379-5579 x206 (ET). Please see our “Repair or Replacement” section of this manual for additional information. BatteryMINDer One-Year 100% Unconditional Money-Back Guarantee This BatteryMINDer product is guaranteed to perform as claimed or WE will refund your full purchase price, including all taxes, shipping or handling cost applicable to the purchase.