Product Manual
BatteryMINDer
®
Models 128CEC1 & 244CEC1
Rev. A2-010516 Page 9 P/N VDC128/244-CEC1-QSS
Quick Start Instructions
Read and thoroughly understand ALL SAFETY Instructions, pages
2 - 7 including Preparing to Charge, Charger Location, DC Connection
Precautions, and Qualifying Your Battery BEFORE proceeding further.
1. Place the Positive (RED) clip on the positive battery terminal.
2. Place the Negative (Black) clip on the negative battery terminal.
3. Select Amperage and Battery Type by pressing:
4. Plug in the BatteryMINDer.
5. Power and Battery Connection light should be GREEN. Indicator will
come on showing state of battery charge and present charging stage.
AMP
BATTERY
TYPE
LED INDICATION TABLE
POWER GREEN
Green Steady AC power connected
Green Flashing ECO mode
BATTERY CONNECTION GREEN RED
Green Steady Battery connected correctly
Red Steady Battery connected incorrectly
BATTERY WEAK AMBER
Amber Steady Battery requires soft-start charging or battery voltage is
< 12.5V / 25.0V after analysis stage
LOAD AMBER
Amber Steady The output current is up to the maximum rating in Float mode
BAD CELL RED
Red Flashing Battery voltage is < 11.5V / 23.0V after analysis stage
TESTING BLUE
Blue Steady Analysis stage
DESULFATING BLUE
Blue Flashing Desulfating pulses are in process
TEMPERATURE COMPENSATION GREEN BLUE
Green Steady Ambient temperature > 27°C/80°F
Blue Steady Ambient battery temperature < 21°C/70°F
VOLTAGE LOW AMBER REJECTED RED
Initial qualication of the battery's condition (at the beginning of Soft-Start stage)
Amber Steady Voltage: 12 Volt: 3 - 10.5V / 24 Volt: 6 - 21V
Red Flashing Voltage: 12 Volt: < 3V / 24 Volt: < 3V (Low Voltage)