Manual
Rev. F-103007 P/N VDC24041AA-S1-MNL
BatteryMINDer
®
Model 24041-AA-S1
Page 28
3. If recharging multiple batteries, 2 or more
complete recharge cycles may be needed.
Repeat full recharge by pressing START but-
ton again. If still RED-blinking, you may need to
charge each battery separately.
Problem:
Battery Condition Indicator lights YELLOW
(After battery has been completely charged)
Solution:
Battery still has an unacceptable level of sulfation
and must stay connected to charger and remain
in Maintenance-Float mode (GREEN blinking indi-
cator) for 72 hours or longer. Then stop charger
by pressing START / RESET / STOP button and
observe Indicator. If still YELLOW repeat (up to 3
full cycles) or until indicator lights GREEN.
Problem:
Battery Condition Indicator lights YELLOW (May
be several causes)
(Before battery is completely charged)
Solution.
Battery can be weak due to sulfation, self dis-
charge or was very deeply discharged.
Attempt a full recharge and recheck after comple-
tion. If still YELLOW follow procedure for (After
battery has been completely charged.)
Problem:
Error and Charge LEDs blink simultaneously
Solution:
Charger has timed out before battery has com-
pletely charged. Reset unit. Repeat reset - full
recharge by pressing RESET button and holding
it down until ALL LEDs flash. Reset charge rate
and battery type, if needed. Press START button
to begin full recharge.