Instruction Manual

Rev. B-012314 Page 8 P/N VDC1500-10MNL
BatteryMINDer
®
&
Plus with SmarTECHnology
®
Model 1500 Series
12V Charger - Maintainer
Automatic Full-Time Desulfator
LED INDICATIONS
POWER DESULFATION CHARGING
FAULT LOW BATTERY MAINTAINING
LED Color
GREEN /
RED
BLUE /
YELLOW
GREEN
1
AC Power connected, Battery
disconnected
ON OFF OFF
2
AC Power connected, battery
disconnected >10 sec., charger in
sleep mode
FLASH OFF OFF
3
AC Power connected, battery initial
condition detected for 3 sec., initial
battery < 10.5V
ON ON OFF
4
AC Power connected, battery initial
condition detected for 3 sec., initial
battery > 10.5V
ON OFF OFF
5
AC Power connected, soft start
charging, bulk charging and
absorption charging
ON FLASH FLASH
6 Sulfation check mode ON OFF FLASH
7
Maintenance charging if battery
voltage < 12.5V at sulfation check
mode
ON ON ON
8
Maintenance charging if battery
voltage > 12.5V at sulfation check
mode
ON FLASH ON
9
Charger output clips shorted,
battery polarity reversed, battery
voltage < 3V
ON OFF OFF
10
Battery timed-out during soft start
charging, bulk charging
FLASH OFF OFF
Remarks: Blue LED flash rate: ON 100 msec., OFF 2 sec.; Green LED Flash rate: ON 0.5 sec., OFF 0.5 sec.
TABLE 2
Applies to
1500 & 1510 models