Manual
Rev. F-103007 P/N VDC12248AA-S1-MNL
BatteryMINDer
®
Model 12248-AA-S1
Page 30
DETAILED SPECIFICATIONS - VDC Model No. 12248-AA-S1 (con’t.)
• Charging Output Control Characteristics
• Charging Flow : Battery condition detect>Soft Start Charge>Bulk Charge>Absorption
Charge>Sulfate Check>Float Charge
• Soft Start Charging Activity conditions: Battery Voltage is over 3 Vdc and less than 10.5Vdc
• Soft Start Charging output current control: (8A mode) 4 ±0.25 Adc
• Soft Start Charging Time Limited: (Stop charge If battery cannot be charged over 10.5V after
6 hrs, Error LED flash indicated) 6 ±0.25 Hours
• Bulk Charging Activity conditions: Battery Voltage is over 10.5Vdc
• Bulk Charging Current control at 8A mode: (Selected by pressing “Until 8A Lit” Button)
• Max. rated output voltage and current: 13.0V at 8Adc 13.6V at 6.50Adc
• Bulk Charging Time Limited: (Stops charge If battery cannot be charged reach 14.1
after 20 hrs, error LED flash indicated) 20 ±1 Hours