SDS

Tub Refinishing Inc., DBA Munro Products
Page 4 of 13
6.
Accidental Release
6.1 Personal precautions, protective equipment and emergency procedures
ELIMINATE ALL IGNITION SOURCES (no smoking, flares, sparks or flames in immediate area). Use only
non-sparking equipment to handle spilled material and absorbent. Do not touch or walk through spilled
material. Stop leak if you can do so without risk. Prevent entry into waterways, sewers, basements or confined
areas. A vapor suppressing foam may be used to reduce vapors. Absorb or cover with dry earth, sand, or other
non-combustible material and transfer to containers. Use non-sparking tools to collect absorbed material.
6.2.
Environmental precautions
Do not allow spills to enter drains or watercourses.
6.3.
Methods and material for containment and cleaning up
CALL CHEMTREC at (800)-424-9300 for emergency response. Isolate spill or leak area immediately for at
least 50 meters (150 feet) in all directions. Keep unauthorized personnel away. Stay upwind. Keep out of low
areas. Ventilate closed spaces before entering. LARGE SPILLS: Consider initial downwind evacuation for at
least 300 meters (1000 feet).
7.
Handling & Storage
7.1. Precautions for safe handling
Handling
Vapors may cause flash fire or ignite explosively.
In Storage
Keep away from heat, sparks and flame.
7.2. Conditions for safe storage, including any incompatibilities Store between 40-100F (4-38C).
Do not get in eyes, on skin or clothing. Strong oxidizing agents.
Do not smoke. Extinguish all flames and pilot lights, and turn off stoves, heaters, electric motors and other
sources of ignition during use and until all vapors are gone.
7.3. Specific end use(s)
Close container after each use. Wash thoroughly after handling.
Prevent build-up of vapors by opening all windows and doors to achieve cross-ventilation
8.
Exposure Controls & Personal Protection
8.1 Control Parameters
CAS No.
Ingredient
Source
Value
0000080-43-3
Dicumyl peroxide
OSHA
No Established Limit
ACGIH
No Established Limit
NIOSH
No Established Limit
Supplier
No Established Limit
OHSA, CAN
No Established Limit
Mexico
No Established Limit
Brazil
No Established Limit
0000110-43-0
Methyl n-amyl ketone
OSHA
100 ppm TWA; 465 mg/m3 TWA
ACGIH
50 ppm TWA
NIOSH
100 ppm TWA; 465 mg/m3 TWA800 ppm IDLH
Supplier
No Established Limit
OHSA, CAN
25 ppm TWA; 115 mg/m3 TWA
Mexico
50 ppm TWA LMPE-PPT; 235 mg/m3 TWA LMPE-
PPT100 ppm STEL [LMPE-CT]; 465 mg/m3 STEL
Brazil
No Established Limit
0000122-51-0
Ethyl orthoformate
OSHA
No Established Limit
ACGIH
No Established Limit
NIOSH
No Established Limit
Supplier
No Established Limit