User Manual

ParSec Reader Installation Manual - Issue:2 - January 1998 - Page 9
T
ERMINAL
B
LOCK
T
ERMINAL
N
UMBER
D
ESIGNATION
1 1 +12 volt supply input
20V
30V
4 +5 volt output
5 Reader inhibit input
6 Long range inhibit input
7 Not used
8 Wiegand data 0 (D0) out
9 Wiegand data 1 (D1) out
10 Wiegand inhibit input
11 Green LED external input
12 Amber LED external input
13 Red LED external input
14 External sounder input
15 Data ground
2 1 External PIR +12V output
2 External PIR 0V output
3 PIR contact input
4 RS-232 data input
5 RS-232 data output
6 RS-232 data ground
7 RS-232 bypass (looped to 8)
8 RS-232 bypass (looped to 7)
9 Tamper loop from S1
10 Tamper loop to S1
11 Alarm reset input
12 Alarm 0V input
13 Alarm relay C
14 Alarm relay NC (powered down)
15 Alarm relay NO (powered down)
T
ABLE
1 - B
ACKPLANE
P
CB
C
ONNECTOR
D
ESIGNATIONS