6. T
AG
T
RANSMISSION
T
IMING
For non-FCC approved types the transmission times are as follows.
When moved When In Tamper Routine report
PS-SAT1-1 3 times at 1.2s intervals at high power Every 0.6s at high power Every hour at high power
PS-PAT1-1 For 2-3 minutes every 0.6s at low power Every 0.6s at high power (Not currently supported)
PS-PET1-1 Every 0.6s continuously at low power Not applicable Not applicable
For FCC approved types the transmit times are as follows:
PS-SAT2-1 7/8 times at 0.6s intervals at high power 7/8 times at 0.6s at high power Every hour at low power
PS-PAT2-1 7/8 timed every 0.6s at low power 7/8 times at 0.6s in high power Every hour at low power
7
T
ROUBLESHOOTING
7.1 Reader Reset
Switch S15 provides a reader reset and should be used, by pressing it for 1-2 seconds, only if
the reader appears to have “hung up”; symptoms may include
(1) Corrupt or no data output.
(2) No scan response to the RAT.
(3) Irregular LED status.
7.2 No response when Tags are activated
Check that the logic PCB is properly plugged into the baseboard PCB. Check that you have
not set the range too short; if tags operate when in tamper only this would verify this. Note
that Demonstration units use the site code 63 and will only read tags with the same site code.