7.7.2 Output Line
7.7.2.1 Voltage Requirements
The following voltage requirements apply to the I/O output VCC (pin 10 of the 12-pin receptacle):
7.7.2.2 Line Schematic
The camera is equipped with one physical output line designated as Output Line 1. The output line
is accessed via the 12-pin receptacle on the back of the camera.
As shown in the I/O schematic, the output line is opto-isolated. See the previous section for the
recommended operating voltage. The absolute maximum voltage is +30.0 VDC. The maximum
current allowed through the output circuit is 50 mA.
A conducting transistor means a logical one and a non-conducting transistor means a logical zero.
Figure 21 shows a schematic circuit you can use to monitor the output line with a voltage signal.
Fig. 21: Typical Voltage Output Circuit
By default, the camera’s exposure active (ExpAc) signal is assigned to Output Line 1. The exposure
active signal indicates when exposure is taking place.
The assignment of camera output signals to the physical output line can be changed by the user.
Voltage Significance
< +3.3 VDC The I/O output may operate erratically.
+3.3 to +24 VDC Recommended operating voltage.
+30.0 VDC Absolute maximum; the camera may be damaged if the absolute maximum is exceeded.
Table 8: Voltage Requirements for the I/O Output VCC