5.7.3 Input Line Response Time
The response times for the input line on the camera are as shown in Figure 36.
Time Delay Rise (TDR) = 1.3 µs to 1.6 µs
Time Delay Fall (TDF) = 40 µs to 60 µs
Level of
Camera’s
Internal Input
Circuit
Voltage Applied
to the Camera’s
Input Line
Time
TDR
TDF
2.2 V
(10.4 V with PLC cable)
1.4 V
(8.4 V with PLC cable)
Not to Scale
Fig. 36: Input Line Response Times