User`s manual

AW00089316000 Physical Interface
Basler ace GigE 59
For more information about input line pin assignments and pin numbering, see Section 5.2 on
page 50.
For more information about how to use an externally generated frame start trigger (ExFSTrig) signal
to control acquisition start, see Section 7.4.3 on page 98.
For more information about configuring the input line, see Section 6.1 on page 67.
Your
Gnd
Your
Gnd
Input
Voltage
+30 VDC
Absolute
Max.
6-Pin
Receptacle
1
2
3
4
5
6
I/O_In_1
I/O_Gnd
In_1_Ctrl
Camera
10
Fig. 35: Typical Input Circuit (Simplified)
Current
Limiter