User`s manual

AW00089316000 Standard Features
Basler ace GigE 261
Note also that the camera briefly exits the "waiting for frame start trigger" status while the input
line changed its state. This happened when input line 1 went high before the frame start trigger
was receceived (see also Figure 97).
When the next frame start trigger was received, the camera checks the state of input line 1.
Input line 1 is found to be low. This corresponds to the address of sequence set 0. Accordingly,
sequence set 0 is selected. Its parameter values are loaded into the active set and are used for
the image acquisition.
When the remaining frame start triggers were received, the camera checks the state of input
line 1. Input line 1 is found to be high. This corresponds to the address of sequence set 1.
Accordingly, sequence set 1 is selected. Its parameter values are loaded into the active set
and are used for the remaining image acquisitions.
When the remaining frame start triggers were received, the camera checks the state of input
line 1. Because the state has not changed and will not for the remaining frame start triggers the
parameter values of sequence set 1 are used for the image acquisitions.
Note that the camera briefly exits the "waiting for frame start trigger" status while the input line
briefly changed its state before the ninth frame start trigger was received..
While frame exposure and readout for the ninth frame start trigger are in progress, the
sequencer feature is disabled. The complete frame is transmitted. The sequencer parameter
values in the active set return to to the values that existed before the sequencer feature was
enabled.
To ensure reliable selection of a sequence set, allow the elapse of at least one
microsecond between setting the states of the input line and the rise of the
frame start trigger signal.
Also, maintain the state of the input line at least for one microsecond after the
frame start trigger signal has risen.
Make sure not to send a frame start trigger while the input line changes its
state. During this period, the camera will not wait for a frame start trigger and
any frame start trigger will be ignored.
Make sure to only send a frame start trigger when the camera is in "waiting for
frame start trigger" status.
For information about possibilities of getting informed about the "waiting for