User`s manual

Standard Features AW00089316000
240 Basler ace GigE
the next sequence set: The parameter values of sequence set 4 are used for the image
acquisition.
When the next frame start trigger was received, the camera checks the current Sequence Set
Executions parameter value. Because the Sequence Set Executions parameter was set to 1
for sequence set 4, this sequence set is only used once and therefore the camera advances to
the next sequence set: The parameter values of sequence set 5 are used for the image
acquisition.
When the next frame start trigger was received, the camera checks the current Sequence Set
Executions parameter value. Because the Sequence Set Executions parameter was set to 2
for sequence set 5, this sequence set is used a second time: The parameter values of
sequence set 5 are used for the image acquisition.
The camera has cycled once through the complete sequence set cycle.
When the next frame start trigger was received, the camera checks the current Sequence Set
Executions parameter value. Because the Sequence Set Executions parameter was set to 2
for sequence set 5, this sequence set can not, after two uses, be used again in the current
sequence set cycle. Therefore the camera advances to the next sequence set: The parameter
values of sequence set 0 are used for the image acquisition.
Another sequence set cycle has started.
The sequencer feature is disabled while frame exposure and readout are in progress. The
complete frame is transmitted and the cycling through sequence sets is terminated. The
sequencer parameter values in the active set return to the values that existed before the
sequencer feature was enabled.