User`s manual
AW00089316000 Standard Features
Basler ace GigE 235
* This parameter is available for timer 1.
**This parameter is only available in auto sequence advance mode.
Sequence Set Configuration
Before the sequencer feature can be used you must populate the sequence sets with the parameter
values of the sequence parameters and store the sequence sets in the camera’s memory. Each
sequence set is identified by a sequence set index number starting from zero. After storing, the
sequence sets are available for use by the sequencer feature.
Some sequence advance modes require the storing of additional settings, for example, the total
number of sequence sets you want to use, the number of consecutive uses of a sequence set or
the source to control sequence set advance. For details about populating sequence sets and
making related settings, see the sections below explaining the sequence advance modes.
Height Color Adjustment Enable
X Offset Color Adjustment Hue
Y Offset Color Adjustment Saturation
Center X Chunk Mode Active
Center Y Chunk Enable
Binning Horizontal Timer Delay*
Binning Vertical Timer Duration*
Pixel Format Timer Delay Timebase*
Test Image Timer Duration Timebase*
Gain Sequence Set Executions**
Processed Raw Enable
Black Level
Make sure the sequencer feature is disabled when configuring sequence sets.
When the sequencer feature is enabled, the values of the sequence parameter
values of the current sequence set cannot be read or changed using the pylon API
or the pylon Viewer. Only those sequence parameter values will be displayed that
were active before the sequencer was enabled. You will not be able to "see" the
parameter values set by the current set.
We recommend that you do not attempt to read or change any of the sequence
parameters when the sequencer feature is enabled.
Because the sequence sets only reside in volatile memory they are lost, if
the camera is reset or switched off. If you are using the sequencer feature,
you must populate the sequence sets after each camera reset or startup.
Sequence sets can not be saved in user sets.