Standard Features AW00089316000
234 Basler ace GigE
The following sequencer parameters determining the sequencer logic are stored in the factory set
(see page 311) with default values:
Sequence Enable, Sequence Set Executions, Sequence Control Source, Sequence Address Bit
Source, Sequence Set Total Number, Sequence Set Index.
Every time the camera is restarted, all sequencer parameters are reset to the default values, e.g.
if you enable and use the sequencer feature with specially set values, and you turn off and on the
camera, the sequencer feature is disabled after restart, and the user-defined parameters are reset
to default values.
Using the sequencer feature has no effect on the camera’s frame rate (see exception).
Exception (acA2500-14)
If you use the acA2500-14 in the overlapped mode of operation, and you activate the sequencer
feature, it depends on the way you use the sequencer, whether it has an effect on the frame rate or
not:
If the camera takes multiple images
... with the same sequence set, overlapped operation is possible and the sequencer feature
has no effect on the camera’s frame rate.
... with alternating sequence sets, overlapped operation is not possible.
The camera must complete the entire exposure/readout process before a new sequence set
can be loaded.
In this case the initial overlapped operation turns out to work as non-overlapped operation.
As a consequence the frame rate can be significantly reduced.
The sequence set currently setting the parameter values of the sequence parameters in the active
set is also called the "current set".
The following parameters are included in each sequence set:
Make sure the sequencer feature is disabled when configuring sequence sets.
When the sequencer feature is enabled, the values of the sequence parameter
values of the current sequence set cannot be read or changed using the pylon API
or the pylon Viewer. Only those sequence parameter values will be displayed that
were active before the sequencer was enabled. You will not be able to "see" the
parameter values set by the current set.
We recommend that you do not attempt to read or change any of the sequence
parameters when the sequencer feature is enabled.
Exposure Time Digital Shift
Enable Acquisition Frame Rate LUT Enable
Acquisition Frame Rate Color Transformation Value
Width Color Transformation Matrix Factor