User`s manual

Image Acquisition Control AW00089316000
118 Basler ace GigE
In global reset release mode, the flash window opens when the frame is triggered and closes after
a time period equal to the Exposure Time Abs parameter setting. Thus, the flash window width (i.e.,
how long the flash window will remain open) is equal to the Exposure Time Abs parameter setting.
For more information about the Exposure Time Abs parameter, see Section 7.6 on page 109.
Line 1
Line 2
Line 4
Line 3
Line 5
Line 6
Line 8
Line 7
Line 9
Line 10
Line 11
Line N-2
Line N
Line N-1
Flash Window Width
= line exposure time
= line readout time
Flash Window
Fig. 60: Flash Window for Rolling Shutter in the Global Reset Release Mode