User`s manual

AW00089316000 Image Acquisition Control
Basler ace GigE 115
You can calculate the total readout time using this formula:
Total Readout Time = [ tRow x (AOI Height) ] + 810 µs
You can calculate the total runtime using the following formula:
Total Runtime = Exposure Time Abs Parameter Setting + Readout Time
The cameras can provide an exposure active output signal that will go high when the exposure time
for line one begins and will go low when the exposure time for line one ends.
When the camera is operating with the rolling shutter in the global release mode, the use of flash
lighting is most strongly recommended. The camera supplies a flash window output signal to
facilitate the use of flash lighting.
For more information about the exposure active output signal, see Section 7.10.1 on page 127.
For more information about the Exposure Time Abs parameter, see Section 7.6 on page 109.
For more information about the flash window, see Section 7.7.2.1 on page 116.
Line 1
Line 2
Line 4
Line 3
Line 5
Line 6
Line 8
Line 7
Line 9
Line 10
Line 11
Line N-2
Line N
Line N-1
Total Readout Time
tRow
Total Runtime
= line exposure time
= line readout time
Frame Start
Triggered
Fig. 58: Rolling Shutter in the Global Reset Release Mode