User`s manual
Image Acquisition Control AW00089316000
112 Basler ace GigE
For more information about the exposure active output signal, see Section 7.10.1 on page 127.
For more information about the Readout Time Abs parameter, see Section 7.11 on page 140.
Line 1
Line 2
Line 4
Line 3
Line 5
Line 6
Line 8
Line 7
Line 9
Line 10
Line 11
Line N-2
Line N
Line N-1
Readout Time
Exposure Time
= line exposure
= line readout
Frame Start
Triggered
Fig. 56: Global Shutter