User`s manual
Image Acquisition Control AW00098504000
74 Basler ace Camera Link
You can also use the Basler pylon Viewer application to easily set the parameters.
For more information about the pylon API and the pylon Viewer, see Section 3.1 on page 19.
Setting the Parameters and Applying the Signal Using Direct Register Access
To set the parameters needed to perform software acquisition start triggering via direct register
access:
Set the value of the Trigger Mode Acquisition Start register to On.
Set the value of the Trigger Source Acquisition Start register to Software.
Set the value of the Acquisition Frame Count register as desired.
Set the value of the Trigger Software Acquisition Start register to 1.
Setting the value of this register to 1 applies a software acquisition start trigger signal to the
camera. The register resets to 0 when execution is complete.
For more information about direct register access, see Section 3.2 on page 21.