User`s manual

AW00098504000 Physical Interface
Basler ace Camera Link 43
Figure 15 shows a typical circuit you can use to monitor the output line with an LED or an opto-
coupler. In this example, the voltage for the external circuit is +24 VDC. Current in the circuit is
limited by an external resistor.
For more information about GPIO pin assignments and pin numbering, see Section 5.2 on page 26.
For more information about setting the GPIO line operation, see Section 6.1 on page 49.
1
2
3
4
4-Pin
Receptacle
Camera
390
4.7k
Gnd
GPIO_Out
U
I/O_Gnd
TLP281
Q1
BC846W
Gnd
120
GPIO_Out_Ctrl
(from FPGA)
GPIO_Gnd
Your Gnd
LED
Output
to You
+24
VDC
Your Gnd
2.2k
Fig. 15: Typical LED Output Signal at +24 VDC for the External Circuit (Example)