User`s manual
Physical Interface AW00098504000
36 Basler ace Camera Link
Voltage Levels When the Standard Power and I/O Cable is Used
The following voltage requirements apply to the camera’s GPIO line when the line is set to act as
an input and a standard power and I/O cable is used:
Voltage Levels When a PLC Power and I/O Cable is Used
The following requirements apply to the camera’s GPIO line when the line is set to act as an input
and a PLC power and I/O cable is used. The PLC power and I/O cable will adjust the voltages to
the levels required by the camera’s GPIO line (see Table 4).
Voltage Significance
+0 to +20 VDC Recommended signal voltage.
+0 to +1.4 VDC The voltage indicates a logical 0.
> +1.4 to +2.2 VDC Region where the transition threshold occurs; the logical state is not defined in this
region.
> +2.2 VDC The voltage indicates a logical 1.
Table 4: Voltage Requirements with the GPIO Set as an Input and Using the Standard Power and I/O Cable
Voltage Significance
+0 to +24 VDC Recommended signal voltage.
+0 to +8.4 VDC The voltage indicates a logical 0.
> +8.4 to +10.4 VDC Region where the transition threshold occurs; the logical state is not defined in this
region.
> +10.4 VDC The voltage indicates a logical 1.
Table 5: Voltage Requirements with the GPIO Set as an Input and Using a PLC Power and I/O Cable