User`s manual

Features AW00098504000
222 Basler ace Camera Link
Loading a Set Using Direct Register Access
To load a saved user set or the default set from the camera’s non-volatile memory into the active
set via direct register access:
Set the value of the User Set Selector register to User Set 1, 2, or 3, or to the Default set as
desired.
Set the value of the User Set Load register to 1.
For more information about direct register access, see Section 3.2 on page 21.