User`s manual
AW00098504000 Features
Basler ace Camera Link 173
signal and set Control B as disabled. In this case, you could point to sequence parameter set 0 or
sequence parameter set 1 by simply using CC1 to set the state of Control A.
Populating the Sequence Parameter Sets
Before you begin using the sequencer feature, you must populate the sequence sets with values
that will be useful for your particular situation. You should use the following procedure to populate
the sequence sets:
Make sure that the sequencer feature is disabled.
Set up your first acquisition scenario (i.e., lighting, object positioning, etc.).
Adjust the camera parameters to get the best image quality with this scenario (you are
adjusting the parameters in the active set).
Use the Sequence Set Selector to select sequence set 0, 1, 2, or 3.
Execute the Sequence Set Store command to copy the sequence parameter values currently
in the active set into the selected sequence set. (Any existing parameter values in the
sequence set will be overwritten.)
Repeat the above steps for the other sequence sets.
There is also a command called Sequence Set Load that can be useful when working with the
sequence parameter sets. If you use the Sequence Set Selector parameter to select a sequence
set and then you execute the Sequence Set Load command, the sequence parameter values in the
active set will be replaced by the values stored in the selected sequence set. This ability can be
useful in two situations. First, if you simply want to see how the parameters currently stored in one
of the sequence parameter sets will affect camera operation, you can load the parameters from that
sequence parameter set into the active parameter set and see what happens. Second, if you want
to prepare a new sequence parameter set and you know that an existing set is already close to what
you will need, you can load the existing sequence set into the active set, make some small changes
to the active set, and then save the active set to one of the other sequence parameter sets.
Replacing the sequence parameter values in the active set via the Sequence Set
Load command is much slower than by involving the Controls A and B. We
therefore recommend to only use the Controls A and B for acquiring images
continuously.
Because the sequence parameter sets reside in volatile memory, they are not
retained if camera power is switched off.