User`s manual
AW00098504000 Features
Basler ace Camera Link 171
The four sequence sets are stored in the camera’s memory and are available for use by the
sequencer feature. Any of the sequence sets only actively controls the operation of the camera after
it was transferred into the active set. The four sequence sets are designated as Sequence Set 0,
Sequence Set 1, Sequence Set 2, and Sequence Set 3.
The parameters included in each sequence set are:
Sequencer Feature Operation
The software module that operates the sequencer feature has two controls designated as Control
A and Control B. Each control can be set to a zero or to a one. As shown below, the combination of
the states of the two controls selects a "set ID", which acts as a pointer to one of the four sequence
sets.
The Sequence Enable parameter is used to enable the sequencer feature. Assuming that the
camera is in the process of continuously capturing images, the sequencer feature operates as
follows:
When the sequencer feature becomes enabled and a frame start trigger was received, the
camera checks the state of Control A and Control B and determines which sequence set is
currently pointed to. The camera immediately replaces the sequence parameter values in the
active set with the values from that sequence set.
When the next image is acquired, the modified active set will be used to control the image
Exposure Time Black Level
Enable Acquisition Frame Rate Digital Shift
Acquisition Frame Rate LUT Enable
Width Light Source Selector
Height Color Transformation Value
X Offset Color Transformation Matrix Factor
Y Offset Stacked Zone Enable
Binning Zone Enable
Pixel Format Zone Top
Test Image Zone Height
Gain
Control B Control A Selects
0 0 Set ID 0 (Sequence Set 0)
0 1 Set ID 1 (Sequence Set 1)
1 0 Set ID 2 (Sequence Set 2)
1 1 Set ID 3 (Sequence Set 3)
Table 12: Controls A and B